ANSI/SMACNA 006-2006 HVAC Duct Construction Standards Eli P. Howard, III Sheet Metal and Air Conditioning Contractors’ National Association. Documents Preceding 3rd Edition HVAC-DCS HVAC Duct Construction Standards --Metal and Flexible –First Edition 1985 –Second Edition 1995. Model Codes ICC International Mechanical Code (IMC) IAPMO Uniform Mechanical Code (UMC) NFPA 90A & 90B. HVAC-DCS ...

Duct Sizing and Construction Tables According to SMACNA - PDF

HVAC Duct Systems Inspections Guide • Third Edition ix TABLES Page B−1 Galvanized Sheet Thickness Tolerances B.3 ...

HVAC Duct Construction Standards - Metal & Flexible | SMACNA

The tables as shown herein are the SMACNA Tables with those interpretations already substi-tuted. By conducting Joint Performance Testing as described in Section VII of the SMACNA HVAC Duct Construction Standards, 2nd ed., 1995,it was found that in some tests, the Ward Angles (E,H and J) permitted a more liberal interpretation of the SMACNA Tables.

HVAC DUCT CONSTRUCTION STANDARDS - SMACNA SMART PINP

duct work to be sealed per smacna hvac table 1-2 5. tdc cnt-jnt-condu-loc @ tdc connector center of duct & @ tdc connector . suburban sheet metal ltd mailing address p.o. box 739 kennedale, tx 76060 physical address 528 s. eden rd. kennedale, tx 76060 phone (817)478-0801 fax (817)483-6571 page 6 of 43 sheet metal standards duct guage and enforcing for 1” ess & drive (+/-) heavy ga metal ...

SMACNA CAD STANDARD

Related Topics . Ventilation - Systems for ventilation and air handling - air change rates, ducts and pressure drops, charts and diagrams and more; Related Documents . Duct Velocity - Calculate velocities in circular and rectangular ducts - imperial and SI-units - online calculator; Ductwork Seal Classes - Ductwork prone to air leakages; Ductwork Support - Ductwork support and recommended ...

Duct System Design Guide - McGill AirFlow

unreinforced duct (wall thickness) table 1-24: 1.69 t-1 flat drive joint accepted as reinforcement: table 1-25: 1.71 unreinforced duct: figure 1-7: 1.73 crossbroken and beaded duct: figure 1-8: 1.74 duct reinforced on two sides: figure 1-9: 1.75 duct reinforced on all sides: figure 1-10: 1.76 reinforcement attachment: figure 1-11: 1.77 duct over 120″ (3048 mm) wide

Give me the perfect SMACNA standards for the ducting sheet ...

HVAC Ducting -Principles and Fundamentals 2012 Instructor: A. Bhatia, B.E. PDH Online | PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.PDHonline.org www.PDHcenter.com An Approved Continuing Education Provider. www.PDHcenter.com PDH Course M246 www.PDHonline.org CONTENTS. 1.0. INTRODUCTION 1 2.0. DUCT COMPONENTS 1 3.0. DUCT CLASSIFICATION 2 3.1 ...

SMACNA Technical Service - utahashrae.org

RE: How to find the minimum thickness of duct with vacuum pressure? pipesnpumps (Mechanical) 26 Sep 11 01:49 ASME piping codes defer to ASME BPV code for calculating external pressures, at least the last time I checked about 5 years ago they did.

ROUND INDUSTRIAL DUCT CONSTRUCTION STANDARDS

AS4254: Duct Classification Standard • Duct pressure classification tables found in the AS 4254 such as low, medium or high pressure • AS4254 explains duct thicknesses, sealing, reinforcement and functional requirements. Refer to table 2.3 for duct thicknesses and reinforcement methods • Changes to 2012 edition as follows:

TT TABLE OF CONTENTS INDUSTRIAL DUCT - Spunstrand

Aluminum Thickness Size Dia. Spiral Pipe 3” - 14” .032 16” - 26” .040 28” - 36” .050 38” - 50” .063 52” - 60” NA Aluminum Thickness Size Dia. Fittings 3” - 14” .040 16” - 26” .050 28” - 36” .063 38” - 50” .071 52” - 60” .090 Galvanized or Stainless Steel Gauge Table for 2005 SMACNA Duct Standard up to

standards for industrial duct construction

I in. seam up to duct width of 42 in. 1 1/2 in. seam for larger ducts May be used on duct interiors Fasten at 2 in. maximum from ends and at 8 in. maximum intervals To ± 10 in. wg Fasten as per L-4 Assemble per Figure 2-17 Ratings may be adjusted with El-rated bar stock or members from Tables 2-29 and 2-30

1 Exam Prep SMACNA - HVAC Duct Construction Standards Tabs ...

Requirements for Standards Verification. General Requirements; Shop standards must be in accordance with the 2005 Third Edition of the SMACNA HVAC Duct Construction Standards. Submittal forms must be completed to indicate all required elements of duct construction. (See prototype Form VFC-1). One form is required for each pressure class of construction to be verified. (Note: When tie rods are ...

(PDF) HVAC SYSTEMS DUCT DESIGN | Erick M C - Academia.edu

McGill AirFlow Corporation has a complete line of single-wall and single-wall lined, round duct and fittings. The internally- lined product incorporates a rigid or semi-rigid fiberglass insulation with an EPA-registered antimicrobial, erosion-resistant coating on the air-side surface. The insulation is available in 1- and 1½-inch thicknesses and has thermal and acoustical properties ...

(PDF) Smacna commercial duct design | Vuong Le - Academia.edu

Thickness - 5/16” Unlimited Shelf Life ... SMACNA TABLE 1-1 DUCT SEALING REQUIREMENTS Seal Class Class Sealing Required Static Pressure Construction Class A All transverse joints, longitudinal seams and duct wall penetrations All transverse joints and longitudinal seams Transverse Joint B C 4” w.g. and up 3” w.g. 2” w.g. In addition to the above, any variable air volume system duct of ...

Industrial Insights Newsletter - Apache Tomcat

Duct system penetrations of walls, floors, ceilings and roofs and air transfer openings in such building components shall be protected as required by Section 607. Ducts in a private garage that penetrate a wall or ceiling that separates a dwelling from a private garage shall be continuous, shall be constructed of sheet steel having a thickness of not less than 0.0187 inch (0.4712 mm) (No.26 ...

HVAC Duct Construction Standards - SMACNA Subscriptions

-Duct is permitted to penetrate three floors or less if it meets all of the following *26 gage minimum (0.019 inch thickness) and located within the cavity of the wall *Duct shall not exceed 100 sq. inches *Annular space must be protected per ASTM E119

Chapter 6 Duct Systems - UpCodes

The thinnest acceptable sheet metal for ductwork used in a single dwelling is 28 gage or 0.013 and 0.018 inches for galvanized and aluminum, respectively. This measurement is for around duct smaller than 12 inches in diameter and a rectangular section no bigger than 8 inches. These figures are for construction according to the most recent ...

Industrial Insights Newsletter

gi sheet thickness as per smacna, US $ 700 - 1000 / Ton, JIS, G3302 1998, ASTM A653M/A924M 2004, SGCC, DX51D, Q195, Shanghai, China.Source from Shanghai Metal Corporation on Alibaba.com.

A GUIDE TO INSULATED HVAC DUCT SYSTEMS

SMACNA is the Sheet Metal and Air Conditioning Contractors National Association. As an ANSI-accredited standards developing organization, SMACNA standards and manuals address all facets of the sheet metal industry, from duct construction and installation to air pollution control, energy recovery and roofing. The voluntary technical standards and manuals developed by SMACNA contractors have ...

Download HVAC Duct Construction Tables According to SMACNA ...

The American National Standard (ANSI/SMACNA 005-2013) expands the scope of the 1999 version, updating the duct materials to include aluminized steel, temperature correction factors for round industrial and minimum decimal thickness for aluminum duct selection tables. Offers a standardized, engineered basis for design and construction of industrial ducts of Classes 1 to 5 air. Includes a spiral ...

CHAPTER 5 EXHAUST SYSTEMS - Dryerbox

GAUGE TO THICKNESS CHART Gauge Stainless Galvanized Sheet Steel Aluminum Fraction inches (mm) inches (mm) inches (mm) inches (mm) 30 0.0125 (0.33) 0.0157 (0.40) 0.0120 (0.30) 0.0100 (0.25) 29 0.0141 (0.36) 0.0172 (0.44) 0.0135 (0.34) 0.0113 (0.29) 28 1/64 0.0156 (0.41) 0.0187 (0.47) 0.0149 (0.38) 0.0126 (0.32) 27 0.0172 (0.43) 0.0202 (0.51) 0.0164 (0.42) 0.0142 (0.36) 26 0.0187 (0.48) 0.0217 ...

and 2010; 2009 and 2012 IMC Duct Insulation and Sealing ...

HVAC Drafting Part 3 - Duct Construction Standard. As per SMACNA the gauges of ducting sheet varies and depends upon the width of the duct and type of application of a particular project.

Duct Leakage Testing - NEBB

3. Fibrous duct construction shall conform to the SMACNA Fibrous Glass Duct Construction Stan-dards or NAIMA Fibrous Glass Duct Construction Standards. 4. Minimum thickness of metal duct material shall be as listed in Table M1601.1.1(2). Galvanized steel shall conform to ASTM A 653. 5. Duct systems shallbe constructed of materialshaving a flame ...

HVAC Air Duct Leakage Test Manual | SMACNA

The dimensional tolerances and metal sheet thickness are selected according to the following criteria: length of the long side of a straight duct, the dimension of the longest side of the connection cross-section of the fitting. Table 1 (see below) provides dimensional tolerances and minimum metal sheet thickness sizes. This is ALNOR's range of rectangular ducts and fittings for ventilation ...